Mr. Heater HS200CV Operations Instructions Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
2
Enerco Group, Inc. |Convection Construction Heater Operating Instructions and Owner’s Manual
70486 Rev. C 04/07
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX-
IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A SAFE DIS-
TANCE AWAY FROM THE HEATER AS RECOMMENDED
BY THE INSTRUCTIONS NEVER USE THE HEATER IN
SPACES WHICH DO OR MAY CONTAIN VOLATILE OR
AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS
GASOLINE, SOLVENTS, PAINT THINNER, DUST PAR-
TICLES OR UNKNOWN CHEMICALS.
THE STATE OF CALIFORNIA REQUIRES THE
FOLLOWING WARNING:
WARNING:
COMBUSTION BY-PRODUCTS PRODUCED WHEN
USING THIS PRODUCT CONTAIN CARBON MONOXIDE,
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER
REPRODUCTIVE HARM).
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
TABLE OF CONTENTS
HEATER SPECIFICATIONS .......................................................... 2
WARNINGS ............................................................................... 2
OPERATING PRECAUTIONS ....................................................... 3
SAFETY PRECAUTIONS .............................................................. 3
ODOR FADE WARNING ............................................................. 4
CAUTION: SHELL EXTENSION INSTRUCTIONS. ......................... 5
OPERATING INSTRUCTIONS ...................................................... 6
SERVICING ................................................................................ 6
SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED ........ 7
80CV - PARTS ............................................................................ 8
200CV - PARTS .......................................................................... 9
WARRANTY ............................................................................. 12
INSTRUCTIONS FOR ORDERING PARTS .................................... 12
SPECIFICATIONS
Type of Gas: ...... For use with Propane Only
Gas Supply
Pressure
to regulator ...... Max.: Bottle Pressure ......Min.: 80CV
= 5 psig (34.5 kPa)
Min.: 200CV
= 15 psig (103 kPa)
regulator out .... 80CV ..............................200CV
= 11" W.C. (2.74 kPa) = 10 psig (68.9 kPa)
Ignition: ............ Piezo Ignitor
Minimum
Ambient
Temp. Rating..... 0°F (-17.8°C)
Model: ............. 80CV ..............................200CV
Rating: .............. 50,000-80,000 Btu/hr ......75,000-200,000 Btu/hr
(8.79 - 23.4 kW) (22.0 - 58.6 kW)
Fuel
Consumption: ... 1.4 to 3.7 #/hr ................3.5 - 9.3 #/hr
(.74 – 1.80 kg/hr) (1.44 - 4.32 kg/hr)
Fuel Orifice
Port No.: ........... 6 ..................................... 6
Fuel Orifice
Port Size: .......... 0.0472" ........................... 0.0320"
(1.20mm) (.813mm)
Page view 1
1 2 3 4 5 6 7 ... 19 20

Comments to this Manuals

No comments