Installation Instructions and Owner’s Manual
Unvented LP-Gas Fired Buddy Wall-Mount Heater
Figure 16
CAUTION: Do not try to adjust heating level by using
equipment shutoff valve.
WARNING: When running heater, set control knob
at “LO” or “HI” locked positions. Poor combustion
and higher levels of carbon monoxide may result
if heater is operated with control knob positioned
between locked positions.
IMPORTANT: Release downward pressure while turn-
ing control knob. Control knob must be locked at the
desired position.
TO TURN OFF GAS TO APPLIANCE
SHUTTING OFF HEATER:
1. Turn control knob clockwise to the OFF posi-
tion.
2. Turn off equipment shutoff valve.
SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)
1. Turn control knob clockwise to the PILOT/IGN
position.
INSPECTING BURNER
Check pilot ame pattern and burner ame pattern
often.
PILOT FLAME PATTERN
Figure 21 show a correct pilot ame pattern. Figure 22
shows an incorrect pilot ame pattern. The incorrect
pilot ame pattern is not touching thermocouple. This
will cause the thermocouple to cool. When the thermo-
couple cools, the heater will shut down. If pilot ame
pattern is incorrect, as shown in Figure 22:
• Turn heater off (see To Turn OFF Gas to Appli-
ance, page 11 for non-thermostat models).
• See Troubleshooting, pages 14 and 15.
Figure 22
BURNER FLAME PATTERN
Figure 23 show a correct burner ame pattern. Figure
24 shows an incorrect burner ame pattern. If burner
ame pattern is incorrect, as shown in Figure 24:
• Turn heater off (see To Turn OFF Gas to Appli-
ance, page 11 for non-thermostat models).
• See Troubleshooting, pages 14 and 15.
Figure 23
Figure 24
CLEANING AND MAINTENANCE
WARNING: Turn off heater and let cool before
servicing.
CAUTION: You must keep control areas, burner and
circulation air passageways of heater clean. Inspect
these areas of heater before use. Have the heater
inspected yearly by a qualied service person. Heater
may need more frequent cleaning due to excess lent
from carpeting, bedding material, pet hair, etc.
Control Knob