Enerco Group, Inc., | Gas-Fired Low-Intensity Infrared Heater Operating Instructions and Owner’s Manual
Canadian Installations1 US Installations2
A= Clearance above grade, 12 inches (30 cm) 12 inches (30 cm)
veranda, porch, deck or
balco
ny
B= Clearance to window or door 6 inches (15 cm) for appliances < 6 inches (15 cm) for appliances <
th
at may be opened 10,000 Btuh (3 kW), 12 inches (30 10,000 Btuh (3 kW), 9 inches (23
cm)
for appliances > 10,000 Btuh cm) for appliances > 10,000 Btuh
(3
kW) and < 100,000 Btuh (30 (3 kW) and < 50,000 Btuh (15
kW),
36 inches (91 cm) for kW), 12 inches (30 cm) for
appliances
> 100,000 Btuh (30 kW) appliances > 50,000 Btuh (15 kW)
C= Clearance to permanently * *
closed
window
D= Vertical clearance to ventilated * *
so
ffit located above the
terminal
within a horizontal
distance
of 2 feet (61 cm) from
the
center line of the terminal
E= Clearance to unventilated soffit * *
F= Clearance to outside corner * *
G= Clearance to inside corner * *
H= Clearance to each side of 3 feet (91 cm) within a height 15
ce
nter line extended above feet (4.5 m) above the *
meter/regulator assembly meter/regulator assembly
I= Clearance to service regulator 3 feet (91 cm) *
vent outlet
J= Clearance to nonmechanical air 6 inches (15 cm) for appliances < 6 inches (15 cm) for appliances <
supply
inlet to building or the 10,000 Btuh (3 kW), 12 inches (30 10,000 Btuh (3 kW), 9 inches (23 cm)
combustion
air inlet to any cm) for appliances > 10,000 Btuh (3 for appliances > 10,000 Btuh (3 kW)
other appliance kW) and < 100,000 Btuh (30 kW), and < 50,000 Btuh (15 kW), 12
36 inches (91 cm) for appliances inches (30 cm) for appliances >
> 100,000 Btuh (30 kW) 50,000 Btuh (15 kW)
K= Clearance to a mechanical air 6 feet (1.83 m) 3 feet (91 cm) above if within 10 feet
supply
inlet (3 m) horizontally
L= Clearance above paved 7 feet (2.13 m) + *
sid
ewalk or paved driveway
loc
ated on public property
M= Clearance under veranda, 12 inches (30 cm) ++ *
po
rch deck, or balcony
1 In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code.
2 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
+ A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
++ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, one of the following shall be indicated:
a)
A minimum clearance value determined by testing in accordance with section 2.19.6, or;
b)
A reference to the following footnote:
Clea
rance in accordance with local installation codes and the requirements of the gas supplier.”
Typical Installation
The Illustration below shows a typical installation of the MHT / HST
tube he
ater. The installation drawing shown has a straight
horizontal venting
arrangement and specifies the minimum space
required for maintenance,
as well as the allowable range of distances
between the
two suspension points.
Detailed venting arrangements are illustrated in following portions
of
this section.
(*) For minimum mounting height in aircraft hangars and public
ga
rages.
X Dimension
Mode
l Min. Max.
MHT-
45 102" 114"
Minimum
Recommended
for servicing
24"
15"
Vent terminal
Exterior
Wall
Outside
wall thickness -
10" max. 1/2" min.
Burner Box
Reflector
Minimum Mou
nting
Heig
ht- 7 feet*
6"
Min
X
1"
Max.
Suspension
Points
Section 4 VENTING
This appliance is certified under the ANS/CSA Standard for Vented
Gas-Fi
red Space Heating Appliances. In accordance with these
stan
dards all sidewall venting must conform to the supplied
diag
ram for Vent Terminal Clearances, which are stated for both
U.S.
and Canadian installations. These clearances should be
compa
red to but not less than those specified in the current ANSI
Z223.1/NFPA 54, National Fuel Gas Code, or CSA B149.1, Natural
Gas
and Propane Installation Code. Clearances not covered in the
table
or above listed codes must comply with local installation
codes
and the requirements of your local gas supplier.
HST- 45 102" 114"