Mr. Heater HST45 Operations Instructions Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
21
Operating Instructions and Owner’s Manual | Gas-Fired Low-Intensity Infrared Heater
BURNER DOES NOT LIGHT
Possible Cause
Air
in the gas line.
Imp
roper gas inlet pressure.
Gas
valve does not open.
Low gas outlet pressure.
BURNER DOES NOT STAY LIT
Possible Cause
Damaged wires between DSI module and electrode.
Faulty DSI module
Damaged
Electrode
Try This….
Pu
rge gas lines.
Check
gas inlet pressure at the 1/8” NPT plugged tap. Gas inlet
pressure should be as follows:
Natural Gas: 5.0”w.c. min.; 10.5” max.
LP
Gas: 11”w.c. min.; 13.0” max.
If
gas inlet pressure does not meet inlet pressure requirements
co
ntact the gas company.
Check
for 24V across valve terminals.
Check
Shutoff On Valve.
IF
NO: Check wiring between the ignition module and the valve.
Repair/replace wires as required. If wiring is OK, replace ignition
mo
dule. IF YES: Replace gas valve.
Check
gas manifold pressure. Measure manifold pressure at the
pressure tap on the gas valve.
Check
gas manifold pressure. Measure manifold pressure at the
pressure tap on the gas valve. Natural Gas: 4.0” w.c. LP Gas: 10.0”
w.c. If manifold pressure does not meet requirements, adjust valve
outl
et pressure with the adjustment screw on the valve. NOTE:
Proper inlet gas pressure must be verified before performing outlet
pressure testing.
Try this…..
Replace wires as required.
Replace DSI module.
Replace Electrode
Enerco Group, Inc.,
Page view 20
1 2 ... 16 17 18 19 20 21 22 23 24

Comments to this Manuals

No comments